Atlanta Generating Sets
|
|
We are a specialized dealer of the following Diesel engines:
|

|
|
Diesel Generating Set 27 kVA / 21, 6 kW
Engine: PERKINS, type 1103A-33G1, watercooled,
1500 rpm
3 Cylinder, Vertical in line, 4 stroke
Induction system: Naturally aspirated...
... see more technical description 
|
|
|
 |
|
|
Diesel Generating Set 80 kVA / 64 kW
Engine: PERKINS, type 1104A-44TG2, watercooled,
1500 rpm
4 Cylinder in line, 4 stroke
Bore: 105,0 mm (4,1 in), Stroke 127,0 mm (5.0 in)...
... see more technical description 
|
|
|
 |
|
|
Diesel Generating Set 100 kVA / 80 kW
Engine: PERKINS, type 1006TG2A, watercooled,
1500 rpm
6 Cylinder, Vertical in line, 4 stroke, Aspiration: Turbocharged
Bore: 100 mm, Stroke 127,0 mm (3,94 / 5.00 in.)...
... see more technical description 
|
|
|
 |
|
|
Diesel Generating Set 135 kVA / 108 kW
Engine: PERKINS, type 1106C-E66TAG2, watercooled,
1500 rpm
6 Cylinder, Vertical in line, 4 stroke, Aspiration: Turbocharged
Stroke 105,0 mm (4,1 in)...
... see more technical description 
|
|
|
 |
|
|
Diesel Generator Set 200 kVA / 160 kW
Engine: PERKINS, type 1306-E87TA300, watercooled,
1500 rpm
6 Cylinder, Vertical in line, 4 stroke
Induction system: Turbocharged AA Charge Cooled...
... see more technical description 
|
|
|
 |
|
|
Diesel Generator Set 250 kVA / 200 kW
Engine: PERKINS, type 1306-E87TA330, watercooled,
1500 rpm
6 Cylinder, Vertical in line, 4 stroke
Induction system: Turbocharged, AA Charge Cooled...
... see more technical description 
|
|
|
 |
|
|
Diesel Generator Set 500 kVA
Engine: PERKINS type 2806C-E16TAG2, watercooled,
1500 rpm
6 cylinder in line, 4 stroke
Induction system: Turbocharged and AA Charge Cooled...
... see more technical description 
|
|
|
 |
|
|
Diesel Generator Set 800 kVA / 640 kW
Engine: PERKINS, type 4006TAG3A, watercooled,
1500 rpm
6 Cylinder in line, 4 stroke, combustion system : direct injection.
Induction system: Turbocharged...
... see more technical description 
|
|
|
 |
|

Automatic Mains Failure Control Panel
Generating Sets with PERKINS Diesel
Separate sheet steel cabinet panel, with a lockable door, comprising:
Instruments:
Voltmeter
Ammeter
Frequency Meter
Hours Run Meter
Coolant Temperature Gauge
Oil Pressure Gauge
Battery Condition Voltmeter
Controls:
Mode Selection Switch: Off/Manual/Auto
Test/Test on Load
Pushbutton Start/Stop/Reset
Voltmeter Phase Sel. Switch, 7 Pos.
Ammeter Phase Sel. Switch, 4 Pos.
Delay on Start Timer (Adjustable)
3 Attempt Start Timer
Delay on Transfer Timer
Delay on Retransfer Timer (Adjustable)
Delay on Stop Timer (Adjustable)
Delay on Stop Timer (Adjustable)
Indicator Test Facility
Protection Shutdown Devices with Indicators:
High Coolant Temperature
Low Oil Pressure
Fail to Start
Status Indicators:
Mains Available
Mains on Load
Generator Available
Generator on Load
Fuel on
Battery Charger:
Constant Voltage, Current Controlled Operation
|
ACCESS 4000
The Access 4000 autostart generating set control panel offers a large number of monitoring and protection features within an extremely compact and user friendly package.
A variety of remote communication options are available allowing the user to access the panel from virtually any location. The design provides for high accuracy for all metering and protection functions, together with the obvious benefits of a large LCD text screen. The use of either an open communication protocol or Modbus ensures compatibility with most building management or supervisory control systems.
The result is a fully automatic configurable generating set controller specifically designed to meet the demands of today´s diverse generating set marketplace.
Digital based circuitry
Digital power metering
Digital engine parameter metering
Open protocol or Modbus communication Interface (RS-422 and RS-485)
Option for Windows compitable remote monitoring packages
Programmable spare output which, when remotely activated, can be utilised for a variety of functions
Optional 20 channel annunciator
Sheet steel cabinet
Four line alpha-numeric liquid crystal display (characters 10x5 mm)
Backlit display
Membrane keypad with tactile feedback
AC metering accuracy +/- 1.5% @ 25°C (plus CT accuracy)
Engine parameter accuracy +/- 1.0% @ 25°C (plus sender accuracy)
Fault log memory
Start sequence diagnostic LEDs
Password protected operator levels
Custom configuration using the integral keypad or a laptop PC
Configuration stored in non-volatile memory
Metering:
AC voltage (phase to phase and phase to neutral)
AC current
Frequency (Hz)
kW, kVAr, kVA, pf (cos Φf) , kWhr
Tachometer (rpm)
Lube oil pressure
Coolant temperature
Battery voltage
Hours run
Start attempt counter
For further informations and to buy a generator set or any spare part please contact us.
top of generator technical specification
|
|
|
|